Due to a recent re-location of manufacturing facilities aligned with a continual product rationalisation program, Master Filtration Limited have reached an agreement with Sogefi Filtration (Coopers Division), whereby we are now the world-wide, exclusive suppliers and distributors of  all Cooper-King original equipment and service spares.

 

Our Letchworth warehouses now hold extensive stocks of spares, including replacement elements in zintec and stainless steel material, to suit both automotive and industrial applications. Gaskets, O rings, blowing unit components, castings and complete blast bottles are now housed in a new unit, where the majority of customer requirements can be picked and despatched on a next day service .

 

Please contact our Sales Department for up-to-date availability and pricing.

 

~~~~~~~~~~~~ ~~~~~~~~~~~~~ ~~~~~~~~~~~~~~~

 

In order to further assist with fault finding, routine maintenance and component identification, the following diagrams and technical information (click for details) will serve as a useful quick reference and addition to the comprehensive Instruction manual & parts list publication No. A73/3

 

 

OPERATIONAL DETAILS

 

The Cooper-King Self Cleaning Air Filter has been designed specifically to deal with severe dust conditions such as can be found in quarries, foundries, construction sites and gravel pits, in addition to many industrial applications. With its self cleaning ability the Cooper-King requires only minimal servicing and thereby significantly reduces operational costs.


Cooper-King remains the only commercially available self cleaning air filter and is used in a wide range of vehicular and industrial equipment applications.

Pressure in the system's blast bottle is built up in a controlled manner by the restrictor in the line filter to 5.6/6.0 kg/cm3 from the vehicle's own compressed air source, or fixed industrial supply, which should be at least 6.7 kg/cm3. This then activates the valve mechanism, in the blowing unit allowing a rapid release of air through the discharge tube into one of the eight element segments. The air blast blows the dust back to the atmosphere guided by the segmented filter skirt.

After pressure is released through the discharge tube the valve plate controlling the blowing sequence is indexed to the next element segment. The blowing interval, determined by the restrictor, is factory-set to suit operational conditions.

MODEL SELECTION (AUTOMOTIVE)

Basic Kit Model No. Air Flow Rating (m3/min) +
KK104/0/1 5.6
KK104/1/1 8.5
KK104/2/1 11.3
KK104/4/1 17.0
KK104/5/1 24.0

+ = Maximum recommended air flow


MODEL SELECTION (INDUSTRIAL)

Basic Kit Model No. Filter Area (m2)
KK4801/1 2.16
KK4801/1X 2.16
KK6801/1 3.25
KK6801/1X 3.25

X = Stainless Steel gauze and end caps on element assembly

 